Testing the physical properties of construction products and materials

Subject of research Type of activity/tested features/method Reference documents
Thermal insulation products in construction and thermal insulation products for building equipment and industrial installations Thermal resistance and properties related to it in steady state
Range: thermal conductivity (0.025 ÷ 0,3) W/(m·K)
PN ISO 8302:1999
Zakres temperatur (-4,5 ÷ 65) °C
Rotary system enabling rotation of the measuring system in the range of 0° ÷ 90°
Method: plate apparatus with a covered heating plate

Subject of research Type of activity/tested features/method Reference documents
Thermal insulation products in construction and thermal insulation products for building equipment and industrial installations Steady-state heat flow through thermal insulation of pipes PN-EN ISO 8497:1999
Range: thermal conductivity (0.025 ÷ 0.1) W/(m K)
Temperature range:
Measuring chamber cold side (-15 ÷ 140) °C
measuring chamber heated side (20 ÷ 200) ºC
Method: testing apparatus with protective cylinders